2 Wire 200 Points Fire Alarm Detection System

This system include 4 zone fire alarm control panel, smoke detector, heat detector, pull station, etc. Conventional 4 zone fire alarm control panel, it have 4 zone, each zone can connect 25pcs 2 wire devices, each zone cable length max up to 5km. Suit for home, small factory, small hotel, etc.

Product Details

This system include 4 zone fire alarm control panel, smoke detector, heat detector, pull station, etc. Conventional 4 zone fire alarm control panel, it have 4 zone, each zone can connect 25pcs 2 wire devices, each zone cable length max up to 5km. Suit for home, small factory, small hotel, etc.

ANKA Sci-Tech Co.,Ltd is one of the leading China 2 wire 200 points fire alarm detection system manufacturers and suppliers, and also a professional company equipped with productive factory, we supply 2 wire 200 points fire alarm detection system with high quality and competitive price.

Product model: AJ-S1004
Feature
An automatic fire alarm system – in general  is made up of smoke, heat & other detectors, manual call points, audible  warning devices, fire alarm control panels with remote notification capability,  which can supply early warning of a developing fire. Such a system, on the  other hand, is unable to assure protection against property damage or loss of  life resulting from a fire. The manufacturer recommends that smoke and/or heat  detectors must be positioned throughout a protected premise following the  recommendations of the current edition of the EN Standard, manufacturer’s  recommendations contained in the Guide for proper Use of System Smoke Detectors, which is made available at no charge to all installing dealers. A study by the  Federal Emergency Management Agency (an agency of the United Europe) indicated  that smoke detectors may not go off in as many as 35% of all fires. A fire  alarm system may not provide timely or sufficient notice, or might not  function, for a diversity of reasons: Smoke detectors may not sense fire where  smoke cannot reach the detectors such as in chimneys, in or behind walls, on roofs, or on the other side of closed doors. Smoke detectors also may not sense  a fire on another level or floor of a building. A second-floor detector, for  example, may not sense a first-floor or basement fire.

Specifications

AC Power

Power

110-270V    AC 50 /60 Hz

Wire    size

minimum    #14 AWG (2.0 mm2) with 600V insulation

Battery    (lead acid only)

Maximum    Charging Circuit

Normal    Flat Charge—27.6V @ 0.8 amp

Maximum    Charger Capacity

18 Amp    Hour batter

Sound    Output Device Circuits

General    Alarm Zones 1 through 16

Operation:    All zones Class B

Normal    Operating Voltage

Nominal    24 VDC (ripple = 100 mV maximum)

Alarm    Current

15 mA    threshold

Short    Circuit Current

42 mA    maximum

Maximum    Loop Resistance

100 ohms

End-of-Line    Resistor

4.7K, ½    watt

Detector    Loop Current is sufficient to ensure operation of two alarmed detectors per    zone

Standby    Current

7.26 mA

Three    Relays Output

Relay    contact rating

2.0 amps    @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)

Nonresettable    24 VDC Power

Maximum    ripple voltage

10 mVRMS

Operating    Voltage nominal 24 volts

Total DC    current available from this output is up to 500 mA

Recommended    maximum Standby current is 150 mA

Clear Picture



why choose us?
- 2000 square meters factory, have capability to supply wide range of products
- Good  quality control ,with competitive prices.
- Prompt  delivery.
- Good  after-sales service.
- No  Minimum order quantity limited. OEM and ODM are also accepted.
- We  locate in Shenzhen of China, easy for export.

Our Services
1.We  guarantee that all our items are "as stated" in their descriptions.  We strive for 100% customer satisfaction on every sale we complete.
2.We are manufacture, there is no middle man, no high markup, so we can provide  quality items yet very competitive price.
3.If you have any questions please contact us first, most are responded within  12 business hours.

Payment

  1. LC

  2. T/T

  3. West Union

  4. Paypal

  5. Trade Assurance

Shipment
1. All  package can sent by FedEx/DHL/UPS/EMS, based on customer requires.
2. Freight  By Sea to Any nearest port of customer country.
3. Freight  by Air to airport of import country.

Company Information
 ANKA is a  high-tech enterprise specializing in the whole process of Research,  Development, Manufacture and Marketing security alarm products. With the  company policy of "Innovative technology, Makes safe life" and the  responsibility of "Progress for protecting people's safety".

FQA
1. Quality of our company.
We are the  manufacturer of alarm system for more than 10 years, we are full of experience  and technology.

2. Quality of our products.
Our  engineers who ever worked in a very famous company of alarm system, all the  products must be strictly inspected before selling.

3. Quality of our services.
All of our  products have a full two-year warranty and low repair rate.

4. Quality of your shipment.
We arrange the  shipment as soon as we get the payment, quickly and professionally.

5. Quality of our sales representatives.
Truly,  Warmly, Patiently, Professionally.

Recommendation

Conventional Fire Alarm Control Panel 

High Stability Tracking IP Addressable Fire Alarm Control Panel

LCD Dispaly PSTN + TCP/IP Home alarm panel system

Fire Alarm Conventional Photoelectric Smoke Alarm Detector

315/433MHz Wireless PIR Detector

Email Us
Feedback
ANKA Sci-Tech Co.,Limited
ANKA Sci-Tech Co.,Limited