Conventional 16 Zone Fire Alarm Monitoring

Conventional 16 Zone Fire Alarm Monitoring

This is conventional type fire alarm control panel, it have 16 zone, each zone can connect 25pcs 2 wire devices, such as smoke detector, heat detector, pull station, etc. Suit for home, small factory, small hotel, etc. ANKA Sci-Tech Co.,Ltd is one of the leading China conventional 16 zone fire...

Product Details

This is conventional type fire alarm control panel, it have 16 zone, each zone can connect 25pcs 2 wire devices, such as smoke detector, heat detector, pull station, etc. Suit for home, small factory, small hotel, etc.

ANKA Sci-Tech Co.,Ltd is one of the leading China conventional 16 zone fire alarm monitoring manufacturers and suppliers, and also a professional company equipped with productive factory, we supply conventional 16 zone fire alarm monitoring with high quality and competitive price.

Product Description
Feature
An automatic fire alarm system – in general  is made up of smoke, heat & other detectors, manual call points, audible  warning devices, fire alarm control panels with remote notification capability,  which can supply early warning of a developing fire. Such a system, on the  other hand, is unable to assure protection against property damage or loss of  life resulting from a fire. The manufacturer recommends that smoke and/or heat  detectors must be positioned throughout a protected premise following the  recommendations of the current edition of the EN Standard, manufacturer’s  recommendations contained in the Guide for proper Use of System Smoke Detectors, which is made available at no charge to all installing dealers. A  study by the Federal Emergency Management Agency (an agency of the United  Europe) indicated that smoke detectors may not go off in as many as 35% of all  fires. A fire alarm system may not provide timely or sufficient notice, or  might not function, for a diversity of reasons: Smoke detectors may not sense  fire where smoke cannot reach the detectors such as in chimneys, in or behind  walls, on roofs, or on the other side of closed doors. Smoke detectors also may  not sense a fire on another level or floor of a building. A second-floor  detector, for example, may not sense a first-floor or basement fire.

Specifications

AC Power

Power

110-270V    AC 50 /60 Hz

Wire size

minimum #14 AWG (2.0 mm2) with 600V insulation

Battery (lead acid only)

Maximum Charging Circuit

Normal Flat Charge—27.6V @ 0.8 amp

Maximum Charger Capacity

18 Amp Hour batter

Sound Output Device Circuits

General Alarm Zones 1 through 16

Operation:    All zones Class B

Normal    Operating Voltage

Nominal    24 VDC (ripple = 100 mV maximum)

Alarm    Current

15 mA    threshold

Short    Circuit Current

42 mA    maximum

Maximum    Loop Resistance

100 ohms

End-of-Line    Resistor

4.7K, ½    watt

Detector    Loop Current is sufficient to ensure operation of two alarmed detectors per    zone

Standby    Current

7.26 mA

Three    Relays Output

Relay contact    rating

2.0 amps    @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)

Nonresettable    24 VDC Power

Maximum    ripple voltage

10 mVRMS

Operating    Voltage nominal 24 volts

Total DC    current available from this output is up to 500 mA

Recommended    maximum Standby current is 150 mA

Clear Picture




why choose us?
- 2000 square meters factory, have capability to supply wide range of products
- Good  quality control ,with competitive prices.
- Prompt  delivery.
- Good  after-sales service.
- No  Minimum order quantity limited. OEM and ODM are also accepted.
- We  locate in Shenzhen of China, easy for export.

Our Services
1.We  guarantee that all our items are "as stated" in their descriptions.  We strive for 100% customer satisfaction on every sale we complete.
2.We are manufacture, there is no middle man, no high markup, so we can provide  quality items yet very competitive price.
3.If you have any questions please contact us first, most are responded within  12 business hours.

Payment

  1. LC

  2. T/T

  3. West Union

  4. Paypal

  5. Trade Assurance

Shipment
1. All  package can sent by FedEx/DHL/UPS/EMS, based on customer requires.
2. Freight  By Sea to Any nearest port of customer country.
3. Freight  by Air to airport of import country.

Company Information
 ANKA is a  high-tech enterprise specializing in the whole process of Research,  Development, Manufacture and Marketing security alarm products. With the  company policy of "Innovative technology, Makes safe life" and the  responsibility of "Progress for protecting people's safety".

FQA
1. Quality of our company.
We are the  manufacturer of alarm system for more than 10 years, we are full of experience  and technology.

2. Quality of our products.
Our  engineers who ever worked in a very famous company of alarm system, all the  products must be strictly inspected before selling.

3. Quality of our services.
All of our  products have a full two-year warranty and low repair rate.

4. Quality of your shipment.
We arrange the  shipment as soon as we get the payment, quickly and professionally.

5. Quality of our sales representatives.
Truly,  Warmly, Patiently, Professionally.

Recommendation

Conventional Fire Alarm Control Panel 

High Stability Tracking IP Addressable Fire Alarm Control Panel

LCD Dispaly PSTN + TCP/IP Home alarm panel system

Fire Alarm Conventional Photoelectric Smoke Alarm Detector

315/433MHz Wireless PIR Detector

Email Us
Feedback
ANKA Sci-Tech Co.,Limited
ANKA Sci-Tech Co.,Limited