NFPA 72, the National Fire Alarm and Signaling Code, requires smoke detectors to be placed in residential settings to ensure fire safety. Specifically, smoke alarms are required inside each bedroom, outside each sleeping area (e.g., hallways), and on every level of the residence, including basements. These requirements apply to both new and existing homes, with some exceptions for existing one- and two-family homes.

Key Requirements:

Inside Bedrooms:

Smoke alarms must be installed in every bedroom or sleeping area.

Outside Sleeping Areas:

Smoke alarms are required outside each separate sleeping area, typically in hallways near bedrooms.

On All Levels:

Smoke alarms are required on every level of the residence, including basements.

Interconnectivity:

In many jurisdictions, smoke alarms must be interconnected so that when one alarm sounds, all alarms in the residence activate.

Battery Backup:

Hardwired smoke alarms should have a battery backup to ensure proper operation during a power outage.

Spacing:

NFPA 72 specifies that smoke detectors should be spaced no more than 30 feet apart, with adjustments for obstructions such as ceiling heights and beams.

Other Considerations:

Cooking Areas:

Smoke alarms should be placed at least 10 feet from cooking appliances unless a closer distance is specifically listed.

Air Flow:

Smoke alarms should be mounted away from direct airflow from supply air registers and return air vents to avoid false alarms or delayed detection.

Ceiling Height:

Smoke alarms should be mounted on the ceiling or on the wall within 12 inches of the ceiling.

Testing and Maintenance:

NFPA 72 also includes periodic testing and maintenance requirements for smoke alarms, including battery replacement.